- Used Measuring & Analysing Instruments[6]
- Integrated Circuits[1]
- Telecom Parts[1]
- Connectors[4]
- Oscilloscopes[5]
- Fiber Optic Equipment[1]
- Weighing Scales[6]
- Mobile Phone Batteries[6]
- Chargers[6]
- HDD Enclosure[4]
- Temperature Instruments[6]
- Level Measuring Instruments[6]
- Laser Rangefinders[6]
- Vernier Calipers[6]
- Width Measuring Instruments[6]
- Other Measuring & Analysing Instruments[6]
- Speed Measuring Instruments[6]
- Sunglasses[6]
- Other Ski Products[6]
- Sports Eyewear[2]
- Flashlights & Torches[6]
- Screwdriver[4]
- MP3 Players[1]
- Digital & Analog-Digital Clocks[4]
- Aquariums & Accessories[5]
- Pressure Gauges[5]
- HDD Players[6]
- Garden Lights[1]
- Buckets[3]
- Other Lights & Lighting Products[2]
- Storage Holders & Racks[1]
- Downlights[1]
- Air Filter[6]
- Air Purifiers[6]
- Ceiling Lights[1]
- USB Flash Drives[6]
- Card Readers[6]
- Paper Crafts[1]
- Wedding Supplies[1]
- Contact Person : Ms. lee lily
- Company Name : Shenzhen Liweihui Technology Co., Ltd.
- Tel : 86-755-29476491
- Fax : 86-755-29476491
- Address : ,,Nanshan Road, Nanshan District
- Country/Region : China
- Zip : 518000
Related Product Searches:KENWOOD CS-4135A 40 MHz Oscilloscope,High Quality,KENWOOD CS-4135A, KENWOOD CS-4135A,CS-4135A
KENWOOD CS-4135A 40 MHz Oscilloscope
Type 150mm rectangular with internal graticule
Accelerating voltage Approx. 12kV
Effective area 8×10 div. (1div=10mm)
Sensitivity 1mV/div to 5V/div (1mV/div., 2mV/div.±5%, 5mV/div to 5V/div. ±3%)Attenuator 1-2-5 steps, 12 ranges, and fine adjustment
Frequency response
DC DC to 40MHz (-3dB) (5mV/div. to 5V/div.) DC to 5MHz (-3dB) (1mV/div. to 2mV/div.)
AC 10Hz to 40MHz (-3dB) (5mV/div. to 5V/div.) 10Hz to 5MHz (-3dB) (1mV/div. to 2mV/div.)
Input impedance 1MΩ ±2%, Approx. 23pF
Rise Time Approx. 8.75ns (40MHz) (5mV/div. to 5V/div.) Approx. 70ns (5MHz) (1mV/div to 2mV/div.)
Crosstalk Below -40dB (at 1kHz sine wave)
Polarity inversion CH2 only
Maximum input voltage 800V p-p or 400V (DC AC peak)
CHOP frequency Approx. 250kHz
Horizontal axis (CH2 input)
Operating modes Switch to X-Y on CH1 : Y-axis / CH2 : X-axis
Sensitivity Same as CH2 vertical axis
Input impedance Same as CH2 vertical axis
Frequency response DC : DC to 500kHz (-3dB)
AC : 10Hz to 500kHz (-3dB)
X-Y phase difference Within 3 degrees at 50kHz
Sweep
Sweep time 0.2µs/div. to 0.5s/div. ±3% 1-2-5 steps, 20 ranges, and fine adjustment
Magnified sweep (×10MAG) ×10, ±5%
Linearity ±3%(×10MAG : ±5%)
Triggering
Trigger sources VERT, CH1, CH2, LINE and EXT
External trigger
Input impedance 1MΩ, Approx. 23pF
Maximum input voltage 84V p-p or 42V (DC ACpeak)
Calibration voltage 1V p-p±3% (Square wave, 1kHz, positive polarity)
Intensity modulation
Input voltage TTL level (dark for positive voltage)
Input impedance Approx. 5kΩ
Frequency response DC to 3.5MHz
Maximum input voltage 84V p-p or 42V (DC AC peak)
CH1 Signal output
Output voltag Approx. 50mV/div. (loaded 50Ω)
Output impedance Approx. 50Ω
Frequency response 100Hz to 20MHz
(within ±3dB, loaded 50Ω)
Trace rotation Enables trace rotation adjustment from front panel
Environmental condition 10°C to 35°C, 85% or less (temperature/humidity for characteristics in spec.)
Operation conditon 0°C to 40°C, 85% or less (temperature/humidity for operation)
Power source 100/120/220/230V AC ±10% (250V AC maximum), 50/60Hz
Power consumption 30W maximum
Case dimensions 290 (W)×150 (H)×390 (D) mm
Maximum dimensions 290 (W)×172 (H)×443 (D) mm
Weight Approx. 6.9kg
Accessories Instruction manual (1) / Probe (PC-54) (2) / Power cable (1)